• 100 kVA Single Phase Pole Mounted Transformer
100 kVA Single Phase Pole Mounted Transformer
discuss personally
Model
DR11-100/10
Basic info
Brand Vziman
Model NO. 100 kva Single Phase Pole Mounted Transformer
Rated capacity 100kVA
Series Single Phase Pole Mounted Transformer
Product Detail

Product Overview

A professional distribution transformer manufacturer with 10 years of expertise, specializes in single-phase pole-mounted transformers for urban and rural power distribution. Designed for 11kV, 12.4kV, 13.2kV, 13.8kV, and 34.5kV input voltages, these transformers deliver outputs such as 240/480V and 120/240V, complying with IEEE C57, ANSI C57, and IEC 60076 standards.

Leading Technological Advantages

  • Enhanced Lightning Resistance: Unique winding technology minimizes surge damage.

  • Superior Mechanical Strength: Low magnetic leakage design with 45° full-oblique step-laminated iron core structure resists short circuits.

Shell & Construction

Precision Manufacturing:

  • Mitsubishi laser cutting and CNC punching ensure mm-level accuracy.

  • ABB robotic welding with laser detection achieves a 99.99998% leak-proof rate.

  • Durable Coating: Electrostatic spray paint offers 50+ years of corrosion resistance (100h salt spray test, hardness ≥0.4).

  • Fully Sealed Design: Cylindrical structure with self-sealing manual pressure relief valve (ANSI-compliant), NEMA-standard hanger brackets, and 30+ year maintenance-free operation.

Core Components

Iron Core

  • High-quality cold-rolled grain-oriented silicon steel sheets from Baowu Steel (China), with mineral oxide insulation.

  • Precision cutting and stacking reduce no-load current, losses, and noise.

Windings

  • Low Voltage: High-grade cable paper-wrapped wires.

  • High Voltage: Polyurethane enamelled round copper wires.

  • Interlayer insulation with dot-adhesive paper ensures coil stability and insulation resistance.

Premium Materials

  • Silicon steel sheets: Baowu Steel Group.

  • Oxygen-free copper: Chinese high-purity grade.

  • Transformer oil: CNPC Kunlun 25# premium oil.

Additional Features

  • High-strength polymer or porcelain low/high-voltage bushings.

  • Ring-type full-copper tinned terminals.

  • Integrated current-limiting fuses and arresters for surge protection.


Product parameters:

  • Capacity: 100kVA 

  • Rated voltage: 13.8kV, 34.5kV

  • Maximum operating voltage (kV) 38.5kV

  • Conditions of use:

  • The temperature:
    Maximum daily temperature (℃) : 40; Minimum daily temperature (℃) : -25; Maximum daily temperature difference (K) : 25; Average temperature of the hottest month (℃) : 30; Maximum annual average temperature (℃) : 20; Average daily relative humidity (≤%) : 95; Average monthly relative humidity (≤%) : 90 

  • Altitude (≤m) : 1000

  • Solar radiation intensity (W/cm2) : 0.1

  • Maximum ice thickness (mm) : 10

  • 10m high from the ground, maintain 10min average maximum wind speed (m/s) : 35

  • Ground horizontal acceleration (M/S2) : 2

  • Installation place: outdoor; 8. Pollution grade: ⅲ

image.png

Ordering instructions:

  • Main parameters of transformer (voltage, capacity, loss and other main parameters) .

  • Transformer use environment (altitude, temperature, humidity, place, etc) .

  • Other customized requirements (tap switch, color, oil pillow, etc) .

  • The minimum order quantity is 1 set, global delivery within 7 days .

  •  The normal delivery period is 30 days, with fast delivery worldwide .

What are the advantages of a single-phase pole-mounted transformer?

  • High Efficiency:Utilizes premium winding materials and advanced manufacturing techniques to achieve superior energy conversion efficiency, reducing operational losses.

  • Low Loss Performance:Constructed with high-grade silicon steel sheets and precision processes, minimizing no-load and load losses for enhanced energy savings and environmental friendliness.

  • Extended Service Life:Premium materials and rigorous manufacturing standards ensure prolonged durability, reducing replacement needs over the product lifecycle.

  • Low Noise Operation:Optimized core and coil design significantly reduces operational noise, making it ideal for noise-sensitive environments like urban areas or commercial buildings.

  • Reliable Performance:Oil-immersed design offers excellent cooling and insulation capabilities, ensuring stable operation in high-power, high-voltage applications.

  • Enhanced Fire Safety:Despite oil-based insulation, modern designs incorporate multi-layer protective measures (e.g., pressure relief valves, fire-retardant coatings) to mitigate risks.

  • Robust Environmental Adaptability:Engineered to withstand harsh conditions, including extreme temperatures, high humidity, and rugged terrain, for versatile deployment.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!